TECHNICAL SPECIFICATION OF Imaging Intensifier with CMOS Detector: To give a programmable/user definable ROI to capture images at high fps (frames per second) 1.      Intensifier                   : 18mm diameter or more2.      Pixel size                    : 6.5 mm or less3.      Active pixels : minimum 2160 ´ 1800 (W´H)4.      Region of Interest      : User definable/programmable5.      Very fast frame rates : Full frame : 50 frames per second or more, 512 ´ 512 ROI at 200fps or more and 2560 ´ 8 ROI at 4000fps or more (ROI: Region of Interest)6.      Spectroscopy : should work in spectroscopy mode with spectrographs and support full binning7.      Digitization                : 16 bit8.      Read noise                 : 3 electrons maximum9.      Interface                     : USB 3.0 with minimum 1GB internal memory10.  Gate time                   : <2ns 11.  Gate pulse delay & gate pulse width: Adjustable from 0 ns to 10 s in 10 ps steps12.  Wavelength range      : 200 – 850 nm13.  Peak QE                     : > 20 % with optimization in 200nm to 400nm wavelength range14.  UV shuttering efficiency : 1:108 or better15.  Sensor type                : Front-illuminated scientific CMOS16.  Minimum cooling temperature: 0°C or lower17.  Insertion delay           : < 20 ns18.  Triggering                   : Externally triggerable with option to monitor/measure the          gate, jitter, indicators to accept external triggers., pre trigger input19.  Digital Delay generator should be integrated and built into detector head20.  Data Range                : 12- bit and 16-bit21.  UV lens (transmission down to 200 nm) and VIS-NIR lens (transmission up to 850 nm or longer) with appropriate adaptors22.  Software for control of detector and data acquisition in spectroscopic and imaging modes. Spectroscopy software should be able to label peaks with elements detected for LIBS23.  Detailed data-sheet with numerical values wherever essential should be submitted. Typical sample test reports characterizing the gate width attained, read noise should also be submitted. Service support record : The supplier should have installed and maintained similar systems in India since last three years. Please provide customer references.Warranty                    : at least 2 years on complete system including intensifier 

Reference: 
ELE/ RSAR/ 028/2017
File: 
Opening Date: 
11/10/17
Closing Date: 
01/11/17
Address: 
Mr. V. Sathyanarayanan SENIOR MANAGER, PROJECT PURCHASE, IC & SR BUILDING, 2ND FLOOR, IIT MADRAS, CHENNAI-600 036.